  1.  
  2.                     AUTO-MIGHT PROFESSIONAL V2.0
  3.  
  4.                 Developed by The Pendulum Group, Inc.
  5.  
  6.                    One-Event Demonstration Version
  7.  
  8.                             USER'S MANUAL
  9.  
  10.  
  11.           Developed by:     The Pendulum Group, Inc.
  12.                             333 W. Hampden Avenue #1015
  13.                             Englewood, Colorado  80110
  14.                  Voice:     (303) 781-0575
  15.                    FAX:     (303) 781-0562
  16.  
  17.  
  18.   Copyright 1993  -  The Pendulum Group, Inc.   All rights reserved.
  19.   Auto-Might Professional is a trademark of The Pendulum Group, Inc.
  20.  
  21.   INTRODUCTION
  22.  
  23.   Welcome to the world of unattended operation of your computer. Auto-Might
  24.   Professional is a powerful program that you can learn to use in only a
  25.   few minutes to automatically execute any program or utility.
  26.  
  27.   Auto-Might Professional is a combination of two memory resident programs,
  28.   an event processor and a keyboard macro builder.  This means it can run
  29.   programs and utilities for you as if you yourself were sitting at the
  30.   keyboard of your computer typing the commands.
  31.  
  32.   To process an event, Auto-Might Professional needs to know three things:
  33.  
  34.   1.  The keystrokes that run the program or utility.
  35.  
  36.   2.  What time of day or on what date the event should be processed.
  37.  
  38.   3.  How frequently the event should be processed. (One Time, Daily,
  39.       Weekly, or Monthly).
  40.  
  41.   Thus Auto-Might Professional gives you the ability to execute programs
  42.   and utilities just once or on a regular basis when the computer is
  43.   unattended, at night, or on holidays.  This demo version of Auto-Might
  44.   Professional allows only one event to be scheduled.
  45.  
  46.   HOW DOES AUTO-MIGHT PROFESSIONAL WORK?
  47.  
  48.   Auto-Might Professional is a memory-resident program, which means it
  49.   stays in your computer's memory regardless of what other programs you may 
  50.   run.  Auto-Might Professional is usually loaded when the system is
  51.   booted, at which time it reads an Auto-Might Professional file containing
  52.   your events.  AutoMight Professional continually monitors its own
  53.   internal clock and calendar, comparing that to the events scheduled.
  54.  
  55.   When the time comes for an event to be processed, Auto-Might Professional
  56.   will attempt to process it.  Note that an Auto-Might Professional event
  57.   can feed keystrokes to a program already running, but normally an
  58.   Auto-Might Professional event starts a program at the DOS prompt.  If
  59.   scheduled, Auto-Might Professional cannot start a second program.
  60.   Auto-Might Professional was designed to be fully compatible with other
  61.   memory-resident programs.
  62.  
  63.   Before executing an event, a warning window will appear on the screen.
  64.   The window displays the name of the event and the event's number.  If no 
  65.   one responds by pressing one of the three function keys, Auto-Might
  66.   Professional will beep once each minute for five minutes.  After five
  67.   minutes, AutoMight Professional assumes the machine is idle and processes
  68.   the event.
  69.  
  70.   If you press the F1 key, Auto-Might Professional will immediately process
  71.   the event.
  72.  
  73.   If you press the F2 key, the warning window will disappear, and
  74.   Auto-Might Professional will "snooze" for 10 minutes. After 10 minutes,
  75.   the warning window will reappear.
  76.  
  77.   If you press the F3 key, Auto-Might Professional will cancel execution of
  78.   the scheduled event for this time only.  That is, if it is a recurring
  79.   event scheduled to be processed each Wednesday, it will still be
  80.   processed next Wednesday.
  81.  
  82.   USING THIS MANUAL
  83.  
  84.   In this manual, the key that we call <enter> may be called "return" in
  85.   other publications.  We call it <enter> because when typing command
  86.   strings in Auto-Might Professional, you specify this key as <enter>.
  87.  
  88.   SOFTWARE INSTALLATION
  89.  
  90.   1.   Install this Demo following the instructions on the diskette and
  91.        those that appear during the installation process.
  92.  
  93.        Note:  The spelling of the Auto-Might Professional program is
  94.        abbreviated as "automite".  DOS does not allow names longer than 8
  95.        characters.
  96.  
  97.   2.   Now add a command to the DOS file autoexec.bat that will load the
  98.        Auto-Might Professional program into memory each time the system is
  99.        booted.  Add the following lines to the autoexec.bat file:
  100.  
  101.        cd\automite
  102.  
  103.        automite
  104.  
  105.        cd\
  106.  
  107.        Note:  These lines must not precede any commands in the autoexec.bat
  108.        file that set the date and time of the computer.  Do not change the
  109.        computer's date or time with the DOS date and time commands after 
  110.        Auto-Might Professional has been loaded.  Otherwise, Auto-Might
  111.        Professional's calendar and clock will not be synchronized with the
  112.        computer's clock and calendar.
  113.  
  114.        At some point while the system is booting, you should see the
  115.        message on your screen:
  116.  
  117.               Auto-Might Professional Event Processor
  118.                       Successfully Installed
  119.  
  120.        This message tells you that Auto-Might Professional is now resident
  121.        in your computer's memory, it has read the event file, and is ready 
  122.        to execute the event found there.
  123.  
  124.   GETTING STARTED WITH THIS DEMO
  125.  
  126.   To start the program, you must have installed the Auto-Might Demo as
  127.   previously described.  Auto-Might Professional must be resident in memory
  128.   to process an event.
  129.  
  130.   Once installed, the following menu screen will appear:
  131.  
  132.        Auto-Might Demo Manual                      F1
  133.        Ordering Information                        F2
  134.        Auto-Key Highlights                         F3
  135.        Why You Need Auto-Might Professional        F4
  136.        Testimonials                                F5
  137.        _________________________________________________
  138.  
  139.        Exit to Auto-Might's One Event           Alt-X
  140.  
  141.  
  142.   You may highlight the field you want or hit the appropriate Function Key.
  143.   The F1 - F5 Keys are all text files which can be printed and reviewed.
  144.   We highly recommend that the Auto-Might Demo Manual be printed so that
  145.   you can understand the basic workings of the software. Additionally, the
  146.   Keystroke Table is very important to the setting up of your one event.
  147.  
  148.   NOTE:  To print any of the text files in this manual, use the DOS copy
  149.          command.  As an example, to print the manual for this demo type:
  150.          COPY MANUAL.TXT PRN
  151.  
  152.   If after exiting this Demo you wish to return at a later time, the
  153.   following procedure should be followed; Begin in the directory that
  154.   contains the Auto-Might Demo, usually called "automite".
  155.  
  156.   This Demo allows you to enter two commands at the prompt of the
  157.   "automite" directory.  These commands are "menu" and "autoedit".
  158.  
  159.   Typing in:  menu <enter>, brings up the menu shown above. Typing in:
  160.   autoedit <enter>,  brings up Auto-Might's One Event.
  161.  
  162.   To bring up the Auto-Might Professional event scheduling screen, called
  163.   autoedit, enter
  164.  
  165.   autoedit
  166.  
  167.   The event scheduling screen is simple to use, but does require that you
  168.   enter the command string precisely.  We suggest you test an event command
  169.   string yourself before entering it into Auto-Might Professional to be
  170.   certain that it will do what you intended.  Since it is critical that
  171.   Auto-Might Professional have the exact key sequence needed to execute the
  172.   event, you may want to write down each keystroke as you test it.
  173.  
  174.   FUNCTION KEYS
  175.  
  176.   Several function key descriptions appear across the bottom of the
  177.   Auto-Might Professional event scheduling screen, which are described
  178.   below.  In addition, several other keys can be used on this screen; they
  179.   are also described below.
  180.  
  181.   F1 - PREVIOUS EVENT
  182.  
  183.   Auto-Might Professional Version 2.0 has an 8 and 32 event version; this
  184.   function key scrolls the event display one event closer to event number
  185.   1.
  186.  
  187.   F2 - NEXT EVENT
  188.  
  189.   Auto-Might Professional Version 2.0 has an 8 and 32 event version; this
  190.   function key scrolls the event display one event closer to the last
  191.   numbered event, either 8 or 32.
  192.  
  193.   F3 - SAVE
  194.  
  195.   This function key saves to disk any changes made to any event.
  196.  
  197.   F5 - COPY
  198.  
  199.   Auto-Might Professional Version 2.0 has an 8 and 32 event version; this
  200.   function key allows you to copy previously defined events.
  201.  
  202.   F4 - CANCEL
  203.  
  204.   This function key erases all information for the event currently
  205.   displayed.
  206.  
  207.   F10 - QUIT
  208.  
  209.   This function key terminates the current editing session, and returns you
  210.   to the DOS prompt.
  211.  
  212.   ENTER  (or RETURN)
  213.  
  214.   This key moves the cursor to the next field on the screen.
  215.  
  216.   UP ARROW
  217.  
  218.   This key moves the cursor up through the fields on the screen.
  219.  
  220.   DOWN ARROW
  221.  
  222.   This key moves the cursor down through the fields on the screen.
  223.  
  224.   Other Editing Keys like the insert, delete, and destructive backspace
  225.   keys can also be used when editing events.
  226.  
  227.   EASY EVENTS
  228.  
  229.   Auto-Might Professional's keyboard macro AutoKey can "record" the 
  230.   keystrokes necessary to execute an event, and assign a key combination to
  231.   that recording.  Auto-Might Professional will enter the key combination
  232.   at the time you specify causing the macro program to replay the pre-
  233.   recorded keystrokes.
  234.  
  235.   When programming an event, simply enter the key combination in the
  236.   Keystrokes field of the Auto-Might Professional event scheduling screen.
  237.   See the Keystroke Table for a list of key combinations supported by
  238.   Auto-Might Professional.
  239.  
  240.   We are unable to provide the macro capability of AutoKey in this demo.
  241.   We are assuming you have knowledge of the use of macros.  For more
  242.   information about AutoKey, go to the AutoMight Demo Menu and press the
  243.   function key F3.
  244.  
  245.   EXAMPLE 1:  DOS DIRECTORY
  246.  
  247.   Demo Event #1 instructs Auto-Might Professional to execute a "dir"
  248.   command, which will display a directory on the screen.  Press <enter>
  249.   twice to skip the date and time. We will come back to these fields later.
  250.  
  251.   REPEAT FREQUENCY
  252.  
  253.   Type D at the Repeats prompt so the event will occur daily. Auto-Might
  254.   Professional will display a "Y" under each normal workday, Monday through
  255.   Friday.  So far you have told AutoMight Professional that you want this
  256.   event to occur every workday of each week.  We want to execute this event
  257.   today.
  258.  
  259.   Press <enter> until the cursor is at the Title field.
  260.  
  261.   EVENT NUMBER, TITLE AND KEYSTROKES
  262.  
  263.   Auto-Might Professional will automatically number this event as number
  264.   "1".  Now, in the Title field enter:
  265.  
  266.   DOS Directory
  267.  
  268.   as the title of this event.  You can enter up to 20 characters for a
  269.   title.  Press enter to move to the Keystrokes field. In the Keystrokes
  270.   field, type the following keystrokes:
  271.  
  272.   dir<ENTER>
  273.  
  274.   You can enter up to 512 keystrokes.  Note that <ENTER> tells Auto-Might
  275.   Professional to simulate pressing the enter key after feeding the
  276.   keystrokes "dir" into the system.
  277.  
  278.   Press <enter> to move to the Date field.
  279.  
  280.   DATE, TIME AND DAY
  281.  
  282.   The fields in the upper left of the screen are for the date, time,
  283.   repeats, and day of the week.  Type:
  284.  
  285.   01 01 1993
  286.  
  287.   in the Date field.  Since this is a daily event, the starting date is not
  288.   important as long as it is some date and/or time in the past.  You must
  289.   use a date and/or time in the future for a one-time event; however, you
  290.   can use a date in the future for the first occurrence of any event
  291.   regardless of the frequency, daily, weekly, or monthly.
  292.  
  293.   Press <enter> to move to the Time field.
  294.  
  295.   Look at the current date and time display in the upper right section of
  296.   the screen, and enter a time in the Time field that is one or two minutes
  297.   from now.  Enter it in 12-hour time, and specify a.m. or p.m.
  298.  
  299.   Note:  When entering times, 12:00 am is midnight and 12:00 pm is noon.
  300.   To enter a time such as half past midnight, you would enter 12:30 am.
  301.  
  302.   SAVE THE EVENT
  303.  
  304.   Press the F3 function key to save the new event and tell the Auto-Might
  305.   Professional event processor about the new event. Press F10 to quit the
  306.   editor and return to DOS.  Now wait for the warning window to be
  307.   displayed.
  308.  
  309.   When the warning window "pops up", press F1 to tell Auto-Might
  310.   Professional it is OK to run the event.  AutoMight Professional will
  311.   simulate typing the commands for a DOS directory; the directory list will
  312.   appear on your screen.
  313.  
  314.   EXAMPLE 2:  COLD OR WARM BOOT THE COMPUTER
  315.  
  316.   You can include an Auto-Might Professional code in an event that will
  317.   cold boot, or warm boot your computer, <CBOOT> and <WBOOT>.  A cold boot
  318.   completely resets your system, as though you turned the power switch off
  319.   and then on again. A warm boot has the same effect as pressing the keys
  320.   ctrl-alt-del simultaneously.
  321.  
  322.   The only keystrokes in this event are the Event Processor's code for cold 
  323.   or warm booting the computer <CBOOT> or <WBOOT>. It is not necessary to
  324.   include the code for enter command. We recommend only <CBOOT> or <WBOOT>
  325.   be entered in the event. No other keystrokes should precede or follow
  326.   this code.
  327.  
  328.  
  329.   CAUTION:  Programs that are running when Auto-Might Professional
  330.   processes a boot code may not have saved data to disk or closed any files
  331.   in use, so data loss is possible. Please be careful!  We strongly suggest
  332.   this function not be used in any event when the /w option (disable
  333.   warning window) was specified at the time Auto-Might Professional was
  334.   loaded.  We also suggest the event title warn that the event re-boots the
  335.   system.
  336.  
  337.   OPTIONS AND FUNCTIONS
  338.  
  339.   This section describes Auto-Might Professional's DOS command line options 
  340.   and the functions available within Auto-Might Professional.  The command
  341.   line options provide quick installation or un-installation of Auto-Might
  342.   Professional, allow you to run Auto-Might Professional without the pop up
  343.   window being displayed, and allow you to reset the cursor when necessary.
  344.   Auto-Might Professional Functions allow you to delay some portion of an
  345.   event (wait codes), print a hardcopy of the screen during or after an
  346.   event, or define an event that cold or warm boots the system.
  347.  
  348.   COMMAND LINE OPTIONS
  349.  
  350.   Auto-Might Professional offers several DOS command line options for use
  351.   with the event processor (automite.com).
  352.  
  353.   /u   Un-install     Un-install removes Auto-Might Professional from
  354.        memory (it is the opposite of entering "automite").
  355.  
  356.   /w   Disable Warning Window   This option disables the warning window.
  357.        When automite is run with this option, Auto-Might Professional will
  358.        not display the warning window prior to processing any event.
  359.        Events run immediately.  You are not warned that an event is about
  360.        to begin.  The event cannot be snoozed or cancelled.
  361.  
  362.   WAIT CODES
  363.  
  364.   You can insert a code between groups of keystrokes in an event that tells
  365.   Auto-Might Professional to wait the specified number of seconds or
  366.   minutes before processing the remaining keystrokes in the event.  This is
  367.   called a Wait Code.  Delays can be from 1 second to 999 minutes and you
  368.   can put as many wait codes in a single event as you wish.
  369.  
  370.   Auto-Might Professional has two wait codes, <waitM-nnn> for minutes or
  371.   <waitS-nnn> for seconds where nnn is a number between 1 and 999.  Wait
  372.   codes can be used in any combination to achieve the desired delay.
  373.  
  374.   PRINT SCREEN CODE
  375.  
  376.   You can include an Auto-Might Professional code in an event that will
  377.   print a hardcopy of the screen at that moment. Auto-Might Professional
  378.   simulates your pressing the shift-prtsc keys.
  379.  
  380.   NOTE:  You may want to insert a wait code of a few seconds in front of
  381.   the <PRTSC> function, to allow time for the event to display the desired
  382.   information on the screen.
  383.  
  384.   TIPS, HINTS AND TRICKS
  385.  
  386.   We have included a few tips, hints, and tricks from current Auto-Might
  387.   Professional users and from our staff.  If you have suggestions, please
  388.   write or call.
  389.  
  390.   MAKING SURE EVENTS RUN EXACTLY WHEN YOU WANT THEM TO
  391.  
  392.   Remember, Auto-Might Professional displays the warning window for five
  393.   minutes before processing the event when the computer is unattended.  For
  394.   example, if you want your event to run unattended at midnight, schedule
  395.   it for   11:55 p.m.
  396.  
  397.   RUNNING COMMUNICATIONS SESSIONS
  398.  
  399.   If your communications software has a command, script, or batch file
  400.   processing capability, we recommend you use that software to perform the
  401.   step-by-step procedures within the communications session.  Use
  402.   Auto-Might Professional to start the communications software and run that
  403.   script or batch file.
  404.  
  405.   BUILDING EVENTS SLOWLY BUT SURELY
  406.  
  407.   Build your event file by adding one keystroke at a time and testing it up
  408.   to that point.  If a step that was supposed to happen instead fails,
  409.   insert a wait code at that point, and continue adding one keystroke at a
  410.   time, or one wait code and one keystroke at a time, until the event is
  411.   complete. If after a wait code keystrokes still disappear, try a longer
  412.   wait period.  Use "Auto-Key" wherever applicable.
  413.  
  414.   TESTING COMPLICATED EVENTS
  415.  
  416.   Divide complicated events into segments.  Build and test each segment as
  417.   suggested above.  After all segments work as desired, combine them into a
  418.   single event, or use "AutoKey" and "Record" the appropriate keystrokes.
  419.  
  420.   DISABLING AN EVENT
  421.  
  422.   To disable an event without erasing it from the event file simply enter
  423.   in all zeros for the starting date.
  424.  
  425.   TECHNICAL INFORMATION - SYSTEM REQUIREMENTS
  426.  
  427.   COMPUTER HARDWARE
  428.  
  429.   Auto-Might Professional operates on IBM PS/2, PC, XT, AT, SX and
  430.   compatible computers.
  431.  
  432.   MEMORY REQUIREMENTS
  433.  
  434.   Once installed, Auto-Might Professional uses less than 8K of memory.  The
  435.   event editor, autoedit, requires approximately 40K of memory when active.
  436.  
  437.   OPERATING SYSTEM
  438.  
  439.   Disk operating systems PC-DOS or MS-DOS versions 2.1 or above.  The
  440.   program does not work in Windows, Desqview, or with Emulation packages.
  441.  
  442.   KEYSTROKE TABLE
  443.  
  444.   Auto-Might Professional also recognizes numerous key combinations.  The
  445.   following table lists the special key combinations supported by
  446.   Auto-Might Professional.
  447.  
  448.  
  449.   Note:  NUM key combinations refer to the keys and characters on the
  450.   numeric keypad, as opposed to those on the typewriter portion of your
  451.   keyboard.
  452.  
  453.  
  454.   SUPPORTED KEY COMBINATIONS
  455.  
  456.  <ALT-!> <ALT-#> <ALT-$> <ALT-%> <ALT-&> <ALT-(> <ALT-)> <ALT-*> <ALT-+>
  457.  <ALT-─> <ALT-0> <ALT-1> <ALT-2> <ALT-3> <ALT-4> <ALT-5> <ALT-6> <ALT-7>
  458.  <ALT-8> <ALT-9> <ALT-=> <ALT-@> <ALT-A> <ALT-B> <ALT-C> <ALT-D> <ALT-E>
  459.  <ALT-ENTER> <ALT-F> <ALT-F1> <ALT-F2> <ALT-F3> <ALT-F4> <ALT-F5> <ALT-F6>
  460.  <ALT-F7> <ALT-F8> <ALT-F9> <ALT-F10> <ALT-G> <ALT-H> <ALT-I> <ALT-J>
  461.  <ALT-K> <ALT-L> <ALT-M> <ALT-N> <ALT-O> <ALT-P> <ALT-Q> <ALT-R> <ALT-S>
  462.  <ALT-T> <ALT-U> <ALT-V> <ALT-W> <ALT-X> <ALT-Y> <ALT-Z> <ALT-^> <ALT-_>
  463.  
  464.  <BACKSPACE> <BACKTAB> <CTRL-─> <CTRL-2> <CTRL-6> <CTRL-@> <CTRL-A>
  465.  <CTRL-B> <CTRL-BACKSPACE> <CTRL-D> <CTRL-E> <CTRL-END> <CTRL-ENTER>
  466.  <CTRL-F> <CTRL-F1> <CTRL-F2><CTRL-F3> <CTRL-F4> <CTRL-F5> <CTRL-F6>
  467.  <CTRL-F7> <CTRL-F8> <CTRL-F9> <CTRL-F10> <CTRL-G> <CTRL-H> <CTRL-HOME>
  468.  <CTRL-I> <CTRL-J> <CTRL-K> <CTRL-L> <CTRL-LEFT> <CTRL-M> <CTRL-N>
  469.  <CTRL-NUM-*> <CTRL-O> <CTRL-P> <CTRL-PGDN> <CTRL-PGUP> <CTRL-Q> <CTRL-R>
  470.  <CTRL-RIGHT> <CTRL-S> <CTRL-T> <CTRL-U> <CTRL-V> <CTRL-W> <CTRL-X>
  471.  <CTRL-Y> <CTRL-Z> <CTRL-[> <CTRL-\> <CTRL-]> <CTRL-^> <CTRL-_> <CTRL-{>
  472.  <CTRL-|> <CTRL-}> <CBOOT>
  473.  
  474.  <DEL> <DOWN> <END> <ENTER> <ESC> <F1> <F2> <F3> <F4> <F5> <F6> <F7> <F8>
  475.  <F9> <F10> <F11> <F12> <HOME> <INS> <LEFT> <NUM-*> <NUM-+> <NUM-─> <NUM-.>
  476.  <NUM-0> <NUM-1> <NUM-2> <NUM-3> <NUM-4> <NUM-5> <NUM-6> <NUM-7> <NUM-8>
  477.  <NUM-9> <PGDN> <PGUP> <PRTSC> <RIGHT> <SHIFT-F1> <SHIFT-F2> <SHIFT-F3>
  478.  <SHIFT-F4> <SHIFT-F5> <SHIFT-F6> <SHIFT-F7> <SHIFT-F8> <SHIFT-F9>
  479.  <SHIFT-F10> <SHIFT-F11> <SHIFT-F12> <TAB> <UP> <WBOOT> <WAITS-xxx>
  480.  <WAITM-xxx>